HT4t Product Specifications

Product Specs
Heated Towel rails turn on and off with the underfloor heating. There are no independent settings for heated towel rails
Modes:
Manual
Program
Settings:
(F) Floor probe
(A) Air Sensor
Possible schedules:
7 day
Programmable:
2 time periods per day
Time:
12-hour clock
Lockable
Standby battery
Touch screen
Temperature differential available
Dimensions:
12cm x 8cm x 1.8cm
Weight:
0.3kg
Volts - electrical block:
230-240 VAC
Volts – thermostat:
5V
Max Capacity:
16 Amps
Maximum temp:
40 degrees Celsius
Minimum temp:
5 degrees Celsius
Frost Protection:
3 degrees Celsius
Floor probe options (kohms):
3 / 10 (default) / 15 / 25 / 50 / 100
Wiring Diagram
Please note that the HT4t wiring is significantly different from all other Heatwell thermostats