Can I put underfloor heating in a shower?
Updated: Oct 12

Yes, underfloor heating can be installed in a shower, with careful planning, provided the shower base is going to be tiled, or have stone or slate. It cannot be used with an acrylic or stainless steel shower base, and it cannot go under a shower tray. If heating is going into the shower, it must be installed before the waterproofing.
What type of shower can have underfloor heating?
A tiled one. The heating cable is laid on the prepared base, covered with fibreglass mesh and screeded, waterproofing is installed, and the tiles, stone or slate go over the top. That construction is what allows heating in a wet area.
A molded acrylic or stainless steel tray rules it out. There is nothing to lay the cable into, and heating cable does not go under a tray.
Heatwell particularly recommends heating in a shower that will be open with no door. An open shower loses heat to the rest of the bathroom. Underfloor heating is a radiant heat coming up from the floor. Underfloor heating in an open shower will keep it warmer.
Does the waterproofing go on before or after?
After. If underfloor heating is going into the shower, the waterproofing must be completed after the heating is installed and screeded. This is not a preference, and it is the single detail most likely to go wrong, because waterproofing is often scheduled before anyone has thought about the floor heating. Tell the water-proofer at the planning stage, not on the day.
What about the floor fall to a drain?
A bathroom floor that falls to a drain can still have underfloor heating. The cable does not run right up to the drain — Heatwell allows 80mm clear of the edge of the drain.
The fall itself is built into the floor before the heating goes in, which is another reason the floor has to be prepared and correct before anyone lays cable.
How do the cables get from the shower to the thermostat?
The heating cable has to leave the wet area and reach where the thermostat flush box is mounted. The thermostat mount needs to be at least 1.5 metres away from the shower. Where the shower entrance is level with the floor, the cables usually run straight out. Where there is a nib wall, like a Marmox nib wall, the cable can be run through it.
Please note that the entrance and exit point in and out of the shower of the heating cable cannot be in the same spot. Underfloor heating cable spacing should never be closer than 55mm.
What adhesive and grout must be used?
In a shower, a two-pot flexible tile adhesive and a latex grout are required. Outside a shower they are preferable but normal grout can be used. Any brand of tile adhesive works over underfloor heating.
Tile adhesive cannot be used directly over the heating in place of self-levelling compound. The serrated trowel used to spread adhesive is a bad thing to drag over a heating cable, and lifting a tile to relay it will very likely damage the cable underneath.
Can underfloor heating go in a wet room?
Yes, on the same conditions: tiled, stone or slate floor, heating before waterproofing, 80mm clear of the drain.
Will the heating dry the shower floor out?
It will dry a tiled floor far faster than an unheated one, which is a meaningful difference in a bathroom with poor ventilation, and it reduces the surface moisture mould needs.
Does heating in a shower need a different thermostat?
No. The thermostat is wall-mounted outside the wet zone and connected by a registered electrician, who issues the code of compliance.